Platelet transfusion deemed ‘harmful’ in patient group
Poor outcome was more likely in the transfusion arm than the standard care arm, with 72.2% and 55.9% of patients, respectively, having an mRS score of 4-6 (OR=2.04; 95% CI, 1.12-3.74; P=0.0195) and 88.7% and 81.7%, respectively, having an mRS score of 3-6 (OR=1.75; 95% CI, 0.77-3.97; P=0.18).
And there was no significant difference between the arms when it came to hematoma growth, with a median of 2.01 mL (interquartile range, 0.32-9.34) in the transfusion arm and 1.16 mL (interquartile range, 0.03-4.42) in the standard care arm (P=0.81).
Safety
Safety endpoints included thromboembolic events, transfusion reactions, and SAEs during hospital admission. The safety analysis was done in the intention-to-treat population (n=97 in the transfusion arm and 93 in the standard care arm) and the as-treated population (n=93 and 91, respectively).
In the as-treated population, the incidence of SAEs was 42% in the transfusion arm and 29% in the standard care arm (OR=1.74; 95% CI, 0.96-3.17). The incidence of any fatal SAE was 24% and 17%, respectively (OR=1.58; 95% CI, 1.77-3.22).