A paraneoplastic potassium and acid-base disturbance

Cleveland Clinic Journal of Medicine. 2019 March;86(3):187-197 | 10.3949/ccjm.86a.18014
Author and Disclosure Information

Release date: March 1, 2019
Expiration date: February 29, 2020
Estimated time of completion: 1 hour

Click here to start this CME/MOC activity.

WHICH TEST TO FIND THE CAUSE?

2. Which is the best test to order next to determine the cause of this patient’s hypokalemic metabolic alkalosis?

  • Serum magnesium level
  • Spot urine chloride
  • Renal ultrasonography
  • 24-hour urine collection for sodium, potassium, and chloride

Algorithms for determining causes of metabolic acid-base disturbances
Figure 1. Algorithms for determining causes of metabolic acid-base disturbances.
The first step in the algorithm for hypokalemic metabolic alkalosis (Figure 1) is to obtain a spot urine chloride measurement. If this value is low, the hypokalemic metabolic alkalosis is volume-responsive; if it is high, the disturbance is volume-independent.

The patient’s loop diuretic is withheld for 12 hours and a spot urine chloride is obtained, which is reported as 44 mmol/L. This high value suggests that a volume-independent hypo­kalemic metabolic alkalosis is present with potassium depletion.

,

As for the other answer choices:

Serum magnesium. Though hypomagnesemia can cause hypokalemia due to lack of inhibition of renal outer medullary potassium channels and subsequent increased excretion of potassium in the apical tubular membrane, it is not independently associated with acid-base disturbances.5

Renal ultrasonography gives information about structural kidney disease but is of limited utility in identifying the cause of hypokalemic metabolic alkalosis.

A 24-hour urine collection is unnecessary in this setting and would ultimately result in delay in diagnosis, as spot urine chloride is a more efficient means of rapidly distinguishing volume-responsive vs volume-independent causes of hypokalemic metabolic alkalosis.6

IS HIS HYPERTENSION SECONDARY? IF SO, WHAT IS THE CAUSE?

Several features of this case suggest that the patient’s hypertension is secondary rather than primary. It is of recent onset. The patient’s family history is noncontributory, and his hypertension is resistant to the use of maximum doses of 3 antihypertensive agents.

3. Which of the following causes of secondary hypertension is not commonly associated with hypokalemia and metabolic alkalosis?

  • Hyperaldosteronism
  • Liddle syndrome
  • Cushing syndrome
  • Renal parenchymal disease
  • Chronic licorice ingestion

Renal parenchymal disease is a cause of resistant hypertension, but it is not characterized by metabolic alkalosis, hypokalemia, and  elevated urine chloride,7 while the others listed here—hyperaldosteronism, Liddle syndrome, Cushing syndrome, and chronic licorice ingestion­—are. Other common causes of resistant hypertension without these metabolic abnormalities include obstructive sleep apnea, alcohol abuse, and nonadherence to treatment.

While treatment of hypertension with loop diuretics can result in hypokalemia and metabolic alkalosis due to the effect of these drugs on potassium reabsorption in the loop of Henle, the patient’s hypokalemia persisted after this agent was withdrawn.8

Causes of hypokalemic metabolic alkalosis with and without hypertension are further delineated in Figure 1.

Additional diagnostic testing: Plasma renin and plasma aldosterone

At this juncture, the differential diagnosis for this patient’s potassium depletion, metabolic alkalosis, high urine chloride, and hypertension has been narrowed to primary or secondary hyperaldosteronism, surreptitious mineralocorticoid ingestion, Cushing syndrome, licorice ingestion, Liddle syndrome, or one of the 3 hydroxylase deficiencies (11-, 17-, and 21-) (Figure 1).

Renin and aldosterone values in hypokalemic metabolic alkalosis with high urine chloride

Although clues in the history, physical examination, and imaging may suggest a specific cause of his abnormal laboratory values, the next step in the diagnostic workup is to measure the plasma renin and aldosterone levels (Table 3).