A Retrospective Analysis of Hemostatic Techniques in Primary Total Knee Arthroplasty: Traditional Electrocautery, Bipolar Sealer, and Argon Beam Coagulation

The American Journal of Orthopedics. 2016 May;45(4):E187-E191
Author and Disclosure Information

In this retrospective cohort study of 280 primary total knee arthroplasties, clinical outcomes relevant to hemostasis were compared by electrocautery type: traditional electrocautery (TE), bipolar sealer (BS), and argon beam coagulation (ABC).

Age, sex, and preoperative diagnosis were not significantly different among the TE, BS, and ABC cohorts. The 3 hemostasis systems were statistically equivalent with respect to estimated blood loss. Wound drainage during the first 48 hours after surgery was equivalent between the BS and ABC cohorts but less for the TE cohort. Transfusion requirements were not significantly different among the cohorts. The 3 hemostasis systems were statistically equivalent with respect to mean change in hemoglobin level during the early postoperative period (levels were measured on postoperative day 1 and on discharge).

As BS and ABC are clinically equivalent to TE, their increased cost may not be justified.

Limitations of this study include its retrospective design, documentation inadequate to account for drainage amount reinfused, and limited data on which clinical insignificance thresholds were based. In addition, reliance on historical data may have introduced bias into the analysis. The historical data used to increase the size of the TE cohort may reflect a period of relative inexperience and may have contributed to the longer operative times relative to those of the ABC cohort (Dr. Levine used ABC later in his career).

Traditional electrocautery remains a viable option in primary TKA. With its low cost and hemostasis equivalent to that of BS and ABC, TE deserves consideration equal to that given to these more modern hemostasis technologies. Cost per case is about $10 for TE versus $500 for BS and $110 for ABC.17 Soaring healthcare expenditures may warrant returning to TE or combining cautery techniques and other agents in primary TKA in order to reduce the number of transfusions and associated surgical costs.